2.PRINTER SETUP
ENGLISH VERSION EO1-33059
2.13 Threshold Setting
E2-69
2.13 Threshold Setting
(Cont.)
(3) Press the
[PAUSE]
key until the target sensor type is displayed.
(4) Set a threshold voltage (calculated in Sensor Adjustment Menu) by
using the
[FEED]
or
[RESTART]
key, as shown below.
Threshold voltage = Midpoint between voltage at a print area and
voltage at a gap/black mark
(5) After choosing a threshold voltage, press the
[PAUSE]
key.
(6) To check for a proper operation, issue the pre-printed media in online.
If an error still occurs even after a manual threshold setting, change
the threshold voltage a little, and retry.
NOTE:
Pressing the
[FEED]
key one time
causes a –0.1V change, up to 0.0V.
Pressing the
[RESTART]
key one
time causes a +0.1V change, up to
+4.0V.
Black Mark Sensor
Feed Gap Sensor
[RESTART]
[FEED]
THRESHOLD<R>4.0V
THRESHOLD<R>3.9V
THRESHOLD<R>3.8V
THRESHOLD<R>0.1V
THRESHOLD<R>0.0V
Black Mark Sensor
THRESHOLD<T>4.0V
THRESHOLD<T>3.9V
THRESHOLD<T>3.8V
THRESHOLD<T>0.1V
THRESHOLD<T>0.0V
Feed Gap Sensor
[PAUSE]
<3> ADJUST SET
THRESHOLD<T>1.4V
<3>ADJUST SET
THRESHOLD<R>1.0V
Summary of Contents for B-SX5T Series
Page 3: ...TEC Thermal Printer B SX5T SERIES Owner s Manual ...
Page 120: ...M EO1 33059 ...