HOW THE AIR CONDITIONER WORKS

Automatic Operation

As shown in Figures 1 and 2, Automatic Operation mode selects the operation based on the room tempera-
ture data (Ta) when operation begins.

Figure 1

Figure 2

The operation mode is selected again after the compressor has remained stopped for 15 minutes.

Hi POWER operation

When you push the Hi POWER button during cooling, heating or A operation, the air conditioner starts the
following operation.

• Cooling operation

The cooling operation is performed at 1°C lower than the temperature setting.

When the room temperature is higher than the temperature setting, the air flow is directed downward.

The fan speed is also set to high*.
Once the room temperature is within 1°C of the set temperature, the air flow is returned to its previous
direction.

  * The noise level increases, according to the fan speed.

• Heating operation (heat pump models)

The heating operation is performed at 2°C higher than the set temperature.

The air flow direction and fan speed are automatically switched according to the operating condition.

ECO operation

When you push the ECO button during cooling, heating or A operation, the air conditioner starts the following
operation. The fan speed is controlled automatically.

• Cooling operation ( )

In the minimum operation zone, where the air conditioner is operated at minimum capacity, overcooling is
prevented by raising the set temperature.

The room temperature is thus regulated between the minimum operation zone and the set temperature.

• Heating operation (

) (heat pump models)

In the minimum operation zone, where the air conditioner is operated at minimum capacity, overheating is
prevented by lowering of the set temperature.

The room temperature is thus regulated between the set temperature and the minimum operation zone.

Dry operation ( )

The dry mode automatically selects the cooling dry operation based on the difference between the set
temperature and the actual room temperature.

The fan speed indicator shows AUTO and low speed is used.

Heat pump models

Cooling only models

Room temperature when operation begins 
or when selected again

Room temperature

Setting temp1
Setting temperature
Setting temperature–1

Cooling operation

Fan only operation

Heating operation

Room temperature when operation begins 
or when selected again

Room temperature

Setting temp1
Setting temperature

Cooling operation

Fan only operation

Summary of Contents for B11MCWE

Page 1: ...Modèle à thermopompe Modèle à froid seul Geräte mit Heizung Geräte nur zur Kühlung Modello con pompa di riscaldamento Modello solo per raffreddamento Modelo con bomba de calor Modelo de refrigeración únicamente ÌïíôÝëï ìå Áíôëßá Èåñìüôçôáò ÌïíôÝëï Øýîçò áðïêëåéóôéêÜ Modelo de bomba térmica Modelo Apenas para Refrigeração Värmepumpsmodell Modell endast för avkylning RAS M10SMUV E RAS M10SMUCV E RB ...

Page 2: ...propriétaire avant de vous remettre Wir danken Ihnen dass Sie sich für ein TOSHIBA Klimagerät entschieden haben Bitte lesen Sie bevor Sie Ihr Klimagerät benutzen diese Betriebsanleitung sorgfältig Lassen Sie sich die Bedienungsanleitung und das Installations Handbuch unbedingt vom Installateur oder vom Lieferanten aushändigen Eine Bitte an den Installateur oder Lieferanten Bitte erklären Sie dem K...

Page 3: ...E 86 PROBLEMI E CAUSE 86 PROBLEMI E CAUSE Riguardanti il telecomando 88 ACCESORIOS 89 PRECAUCIONES DE SEGURIDAD 89 NOMBRE DE LOS COMPONENTES 91 DESCRIPCIÓN DE LOS BOTONES DE LA SECCIÓN DEL RECEPTOR 92 DESCRIPCIÓN DE LOS BOTONES DEL CONTROL REMOTO 93 NOMBREY FUNCIONES DE LOS INDICADORES DEL CONTROL REMOTO 94 PREPARACIÓNY PRUEBA ANTES DEL USO 95 USO DEL CONTROL REMOTO 96 FUNCIONAMIENTO AUTOMÁTICO 97...

Page 4: ...r the air filter is detailed for the service engineer and not for the customer Be aware of the potential health issues which could arise due to the exposure of the human body to cold draughts or by over cooling the room When you notice something abnormal with the air conditioner smells like some thing scorching poor cooling etc immediately turn off the main switch and the circuit breaker from the ...

Page 5: ...ir into the room Poor ventilation causes oxygen shortage Do not place any combustion appliance in a place where it is directly exposed to the air flow of the air conditioner otherwise it may cause a combustion When the air conditioner is used in a closed room be careful to ensure sufficient ventilation within the room Poor ventilation causes oxygen shortage Do not touch any switches with wet hands...

Page 6: ...harge louver of discharge port Change the direction of the air to be discharged according to cool heat mode Suction inlet grille The air in the room is sucked in through this grille Air filter Removes dust particles Attached to inlet grille Receiver section Remote controller Pipes and electric wires Air outlet Air inlet Side and rear Outdoor unit ...

Page 7: ... flash rapidly 5 times per second when a safety protection feature is activated 3 TIMER indicator Yellow 4 Remote controller sensor RESET button If you misplace or loose the remote controller or the batteries are fully discharged push the RESET button 1 Push the RESET button to start the automatic operation AUTO Push this button again to stop operation See page 17 4 1 3 2 ...

Page 8: ...ng A receiving beep is heard 6 Set louver button FIX Push this button to adjust the air flow direction A receiving beep is heard 7 Off timer button OFF Push this button to set the OFF timer 8 On timer button ON Push this button to set the ON timer 9 Reserve button SET Push this button to reserve time settings A receiving beep is heard 10 Cancel button CLR Push this button to cancel ON timer and OF...

Page 9: ... mark is displayed when the button is not pushed for more than 3 seconds while the mark is flashing Push another button to turn off the mark 8 ECO TIMER display Indicates when the ECO TIMER is in operation Each time you push the ECO button the display changes in sequence between 1 3 5 or 9h 9 A B change indicatior remote controller When the remote controller switching function is set B appears on ...

Page 10: ...set the clock of the remote controller using the procedures given in this section The clock panel on the remote controller indicates the time regard less of whether the air conditioner is in use or not Initial setting When batteries are inserted in the remote controller the clock panel indicates AM 0 00 and flashes 1 TIMER button Push the TIMER button to set the current time Each time the TIMER bu...

Page 11: ... you plan to use the fluorescent lights in the same room where the air conditioner operates consult your local dealer If other electrical appliances react to the remote controller of the air conditioner either remove these appliances or consult your local dealer Location of the remote controller Keep the remote controller where its signals can reach the receiver on the panel maximum distance is 7 ...

Page 12: ...ed conditions manually Fan speeds and louver position can be changed When it is changed the MODE is also changed from AUTO to A At the same time fan speed indication is displayed Stop START STOP button Push this button to stop the air conditioner AUTOMATIC OPERATION AUTO CHANGEOVER When you set the air conditioner in A mode or switch over from AUTO operation because setting may have been changed i...

Page 13: ... only models 4 Fan speed button FAN Select one of AUTO LOW LOW MED MED HIGH The OPERATION lamp green on the panel of the indoor unit illuminates Operation starts after approximately 3 minutes If you select FAN ONLY mode the unit will start immediately The Fan only mode does not control temperature Therefore perform only steps 1 2 and 4 to select this mode Stop START STOP button Push this button to...

Page 14: ...IMER The air conditioner stops after operating for the set time 1 3 5 or 9 hours 1 ECO button Push the ECO button during operation There is a short beep and the timer indicator comes on The time at which the air conditioner will stop is indicated on the remote controller display 1H about 1 hour after the current time Push the button again while 1H is displayed about 3 seconds to change to the 3H i...

Page 15: ... timer is displayed and the timer starts 4 CLR button Push the CLR button to cancel the timer setting CAUTION When you select the timer operation the remote controller automatically transmits the timer signal to the indoor unit at the specified time Therefore keep the remote controller in a location where it can transmit the signal to the panel properly If you do not push the SET SET button within...

Page 16: ... adjust the ON timer 3 Push the OFF button 4 Push the TIMER button to adjust the OFF timer 5 Push the SET SET button Either ON or OFF timer function which ever is the closest to the current time is activated first If the same time is set for both the ON and OFF timers no timer operation is performed Also the air conditioner may stop operating Every day combined timer Setting both ON and OFF timer ...

Page 17: ... All icons are currently displayed except for the clock display and P mark flashes 2 MEMO button Push and hold the MEMO button for more than 3 seconds while the display flashes The P mark is indicated and the setting is memorized If you do not push the MEMO button within 3 seconds or if you push another button the MEMORY setting is cancelled Operation modes which can be memorized with using the ME...

Page 18: ...ow louver direction within the range that is displayed In subsequent operations the air flow is automatically set to the direction that you set the louver using the FIX button In HEAT FAN ONLY operation In COOL DRY operation In all modes To automatically swing the air flow direction Perform this function when the air conditioner is operating 1 SWING button Push the SWING button on the remote contr...

Page 19: ...utton during cooling heating or A operation the air conditioner starts the following operation The fan speed is controlled automatically Cooling operation In the minimum operation zone where the air conditioner is operated at minimum capacity overcooling is prevented by raising the set temperature The room temperature is thus regulated between the minimum operation zone and the set temperature Hea...

Page 20: ...cessary Window curtains In cooling close the curtains to avoid direct sunlight In heating close the curtains to keep the heat in Get uniform circulation of room air Adjust the air flow direction for the even circulation of room air TEMPORARY OPERATION This function is used to operate the unit temporarily in case you take a remote controller for the right one or the batteries are fully discharged P...

Page 21: ...eration Cleaning of the remote controller CAUTION Use a dry cloth to wipe the remote controller A cloth dampened with cold water may be used on the indoor unit if it is very dirty Never use a damp cloth on the remote controller Do not use a chemically treated duster for cleaning nor leave such materials on the unit for long It may damage or fade the surface of the unit Do not use benzene thinner p...

Page 22: ...duced or stop to prevent blowing cold draft At this time the outdoor unit stops Defrosting operation If the outdoor unit frosts during the heating operation defrosting starts automatically for approximately 2 to 10 minutes in order to maintain the heating capacity The fans in both indoor and outdoor units stops during the defrosting operation During the defrosting operation the defrosted water dra...

Page 23: ...ditioner in a place where it is usually exposed to strong winds such as in a sea side area or on the roof of the upper floor of a building Do not install the air conditioner in a place where sulfurous gases are generated such as in a spa Do not install the air conditioner in a vessel or a mobile crane Be careful with noise or vibrations Do not install the air conditioner in a place where noise or ...

Page 24: ...en flow of the refrigerant is changed for defrosting Resultant water of automatic defrosting in heating operation drains from outdoor unit Air flow changes though the FAN button is not set to the AUTO mode When the temperature of the blown air drops in heating operation the air conditioner automatically changes or stops air flow from the indoor unit not to prevent the person in the room feeling co...

Page 25: ... MODE indi cated on the display is FAN ONLY FAN ONLY Reasons The temperature can not be set during fan only operation The Display Goes Off Symptoms The indication on the display disappears after a lapse of time The TIMER indicators go off after a certain time has elapsed Causes Check whether the timer operation has come to an end when the OFF TIMER is indicated on the display Check whether the tim...

Reviews: