6
MMU-AP___2H2UL
E15-3C1
MMU-AP0362H2UL, AP0422H2UL
9.5"(241.5)
33.1"(840) Unit external dimension
37.4"(950) Panel external dimension
30.7"(780) Hanging bolt pitch
5.2"(132)
12.6"(319)
0.5" (12)
Z view
1.2" (30)
7.4"(187)
6.1"(155)
1.1"
(28.5)
2.4"
(61)
1.3"
(32)
2.2"
(57)
2.5"
(64)
16.4"(416.5)
37.4"(950) Panel external dimension
Z
10.6"(269)
12.7"(323)
7.4"(189)
2.8" (72)
4.2"
(106.5)
33.1"(840) Unit external dimension
16.1"(408)
4.4"
(112)
6.8"(172)
1.7"
(42)
Ceiling bottom
surface
Ceiling
bottom
surface
Indoor unit
Ceiling
bottom
surface
Ceiling panel
Ceiling bottom
surface
Ceiling panel
(Sold separately)
Hanging bolt 3/8"(M10)
(To be procured locally)
Electric
parts box
Ceiling bottom surface
Ceiling
bottom
surface
Drain pipe
connecting port
2.3"
(58)
1.6"
(40)
9.9"(251)
11.1"(281)
12.0"(306)
Hole for remote
controller wires
Conduit hole(Knockout)
Hole for power
supply cable
45
Refrigerant pipe
connecting port
(Liquid) 3/8"(9.5)
Refrigerant pipe
connecting port
(Gas) 5/8"(15.9)
27.2±0.8"(690) Hanging bolt pitch
Knockout for simple OA
For 3.9"(100)
39.4"(1000)
or more
Space required for installation
0.6"(15) or more
39.4"(1000)
or more
39.4"(1000)
or more
0.6"(15) or more
33.9" to 35.8"(860 to 910) Ceiling open dimension
33.9" to 35.8"(860 to 910) Ceiling open dimension
7.9"(200)
( 17.7"(450))
7.9"(200)
( 17.7"(450))
Check port
When a fresh-air inlet box is
installed, make check port
at the side of the fresh-air
inlet box.
Check port
Drain-up standing-up size
11.8"(300)
or less
Stand-up
26.0"(661)
or less
Stand-up
33.5"(850) or less
Indoor unit
Ceiling bottom
surface
Unit:in (mm)
+00E15-3C1_01EN.book Page 6 Thursday, March 24, 2016 11:25 AM