Toshiba XXXXXXX(
X
/X)
– 17 –
4-way Air Discharge Cassette Type
Owner’s Manual
11.
ADVANCED SETTINGS
Swing mode
1
Push
for at least four seconds when
the air conditioner is not working.
•
, symbol, and numbers flash.
2
Push
(left side of the button) to select
an indoor unit to be set.
• Each time you push the button, the unit numbers
change as follows:
The fan of the selected unit runs and the louvers
start swinging.
3
Push TIME
buttons to select a swing
type.
Three types of swings are available:
•
Standard swing
The four louvers swing in the same direction.
•
Dual swing
Louvers
01
and
03
are directed and swing in
one direction, and/then louvers
02
and
04
are
directed and swing in the opposite direction.
(When louver
01
is directed downward, louver
02
is directed horizontally.)
•
Cycle swing
The four louvers swing independently at
respective timings.
CAUTION
• Do not set the SET DATA to “0000”.
(This setting may cause a failure of the louvers.)
4
Push
button.
5
Push
button to complete the setting.
1
2
3
Not
display
UNIT No.
1-1
UNIT No.
1-2
UNIT No.
1-3
UNIT No.
1-4
SET DATA
Swing of louvers
0001
Standard swing
(Factory default)
0002
Dual swing
0003
Cycle swing
04
02
03
01
Refrigerant
pipe
Drain
pipe
SET DATA
17-EN
+00EH99933501_00Ta.book Page 17 Tuesday, November 24, 2009 2:25 PM