background image

Toshiba

AIR-DISCHARGE DIRECTION KIT FOR AIR CONDITIONER (SPLIT TYPE)

Air-Discharge Direction Kit 
(for 4-way air discharge cassette Type)

Model name:

Air-discharge direction kit

TCB-BC1602UUL

Installation Manual

Installation Manual

Air-discharge direction kit

1

English

Manuel du proprietaire

Climatiseur 

(Type à deux éléments)

7

Français

+00EH99678401.BOOk  Page 1  Friday, November 13, 2009  2:38 PM

Summary of Contents for CARRIER TCB-BC1602UUL

Page 1: ...ir Discharge Direction Kit for 4 way air discharge cassette Type Model name Air discharge direction kit TCB BC1602UUL Installation Manual Installation Manual Air discharge direction kit 1 English Manuel du proprietaire Climatiseur Type à deux éléments 7 Français ...

Page 2: ...read the installation manual supplied with the ceiling panel carefully Please use this kit when controlling the air direction in 3 way or 2 way air flow depending on the installation location status of the indoor unit 1 APPLICABLE MODELS AND APPLECATIONS 2 ACCESSORIES The following parts are included MODEL Applicable model Application TCB BC1602UUL SP180 to SP420 Controlling the blockage of 3 way ...

Page 3: ...the edges of the indoor unit external surface without blocking the concaved portions of the drain pans If the packings are not put bending along the edge of the indoor unit external surface the dew condensation may occur Refer to Fig 1 and 3 The size adjustment is required for the packing which are attached on the wind shield C Cut 1 58 40 mm to adjust its size in 16 5 x 4 3 420 mm x 110 mm Fig 1 ...

Page 4: ...age portions of the air flow outlet are specified depending on the models Do not specify the blockage of the airflow outlet other than specified in the table below Limited models only 3 way air flow Available for all models Available for all models Available only for SP180 to SP240 Available only for SP300 to SP420 2 way air flow Available for all models Available for all models Available for all ...

Page 5: ... stops 1 Push buttons simultaneously for more than 4 sec The unit No displayed at first shows the indoor unit address of the header unit in group control operation The fan operation of the indoor unit header unit selected at this time is carried out 2 Every time when UNIT Left button is pushed the No in the group cotrol operation are displayed in order The fan operation of the indoor unit selected...

Page 6: ...The selected louver starts to swing 4 Select the code 0001 by pushing the TIME buttons 5 Push the button to define the setting contents After the setting contents is defined the mark lights Return to step 3 if there are other two wind shields 6 Push the button to exit the setting F1 is displayed in the CODE No on the remote controller display This means that the 01 louver shown on the illustration...

Page 7: ... 6 Air dischage direction kit Installation Manual EN MEMO ...

Page 8: ...EH99678401 ...