1-8-1
E7A70TR
TROUBLESHOOTING
NOTE: BOARD MEANS PRINTED CIRCUIT BOARD.
FLOW CHART NO.1
The power cannot be turned on.
Is the fuse normal?
Is normal state restored when once unplugged
power cord is plugged again after several seconds.
Is the EV+5V line voltage normal?
Check each rectifying circuit of secondary circuit
and service it if defective.
See FLOW CHART No.2 <The fuse blows out.>
Check for lead or short-circuiting of primary
circuit component and service it if defective.
(Q1001,Q1002,Q1003,T1001,D1001,D1002,
D1003,D1004,D1006,D1014,C1004,C1005,
C1015)
Yes
Yes
Yes
No
No
No
FLOW CHART NO.2
The fuse blows out.
After servicing, replace the fuse.
Check the presence that the primary component
is leaking or shorted and service it if defective.
Check the presence that the rectifying diode or circuit
is shorted in each rectifying circuit of secondary side
and service it if defective.
FLOW CHART NO.3
When the output voltage fluctuates.
No
Yes
Does the secondary side photo coupler circuit
operate normally?
Check the circuit and service it if defective.
(IC1001, D1007, D1009)
Check the circuit and service it if defective.
(IC1001, Q1055, D1064, D1067)
FLOW CHART NO.4
When buzz sound can be heard in the vicinity of power circuit.
Check if there is short circuit on the rectifying diode and the circuit in each rectifying circuit of secondary side and
service it if defective. (D1051,D1054,D1055,D1056,D1058,D1063,D1068,IC1503,IC1504,Q1053,Q1054,Q1057,Q1063)
No
Yes
FLOW CHART NO.5
-FL is not outputted.
Is the supply voltage of -25V fed to the anode of
D1054?
Check D1054 and their periphery, and service it if
defective.
Check for load circuit short-circuiting or leak, and
service it if defective.