DeviceNet Module Installation and Operation Manual
27
Table 43. Instance 101/151 – Read Parameter F268 (Initial value of UP/DOWN frequency).
Table 44. Instance 101/151 – Read Parameter FE04 (Voltage of DC bus).
Table 45. Instance 101/151 – Write 60 Hz to Parameter F563
(Preset Speed 1, Communication Number 0018).
1 – Error code key.
1 — Data out of range
2 — Bad address
3 — Read only
4 — Stop to modify or permission error
5 — All other
For bytes 0 - 3, refer to
Instance
Byte
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Hex
Output
Instance 101
5, 4
0
0
0
0
0
0
1
0
0
1
1
0
1
0
0
0
0x0268
7, 6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Input
Instance 151
(F268 set to
60.0 Hz)
5, 4
0
0
0
0
0
0
1
0
0
1
1
0
1
0
0
0
0x0268
7, 6
0
0
0
1
0
1
1
1
0
1
1
1
0
0
0
0
0x1770
Instance
Byte
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Hex
Output
Instance 101
5, 4
0
0
1
1
1
1
1
0
0
0
0
0
0
1
0
0
0x3E04
7, 6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Input
Instance 151
(FE04 set to
94.49%)
5, 4
0
0
1
1
1
1
1
0
0
0
0
0
0
1
0
0
0x3E04
7, 6
0
0
1
0
0
1
0
0
1
1
1
0
1
0
0
1
0x24E9
Instance
Byte
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Hex
Output
Instance 101
5, 4
1
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0x8018
7, 6
0
0
0
1
0
1
1
1
0
1
1
1
0
0
0
0
0x1770
Input
Instance 151
(OK)
5, 4
1
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0x8018
7, 6
0
0
0
1
0
1
1
1
0
1
1
1
0
0
0
0
0x1770
Input
Instance 151
(NG)
(Error code
1
)
5, 4
1
1
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0xC018
7, 6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0x0001