DeviceNet Module Installation and Operation Manual
35
FD06 — Input Terminal Board Status
FD07 — Output Terminal Board Status
14
Stop after instantaneous power off
-
Dec. Active stop
Refer to F256 value
15
Stop after F013 (LL) continuance time
-
Dec. Active stop
Refer to F302 value
Bit
TB Name
Function (Parameter)
0
1
0
F
Input TB Function select 1 (F111)
Off
On
1
R
Input TB Function select 2 (F112)
2
ST
Input TB Function select 3 (F113)
3
RES
Input TB Function select 4 (F114)
4
S1
Input TB Function select 5 (F115)
5
S2
Input TB Function select 6 (F116)
6
S3
Input TB Function select 7 (F117)
7
S4
Input TB Function select 8 (F118)
8
LI1
Input TB Function select 9 (F119)
9
LI2
Input TB Function select 10 (F120)
10
LI3
Input TB Function select 11 (F121)
11
LI4
Input TB Function select 12 (F122)
12
LI5
Input TB Function select 13 (F123)
13
LI6
Input TB Function select 14 (F124)
14
LI7
Input TB Function select 15 (F125)
15
LI8
Input TB Function select 16 (F126)
Bit
TB Name
Function (Parameter)
0
1
0
OUT1
Output TB Function select 1 (
F130
)
Off
On
1
OUT2
Output TB Function select 2 (
F131
)
2
FL
Output TB Function select 3 (
F132
)
3
OUT3
Output TB Function select 4 (
F133
)
4
OUT4
Output TB Function select 5 (
F134
)
5
R1
Output TB Function select 6 (
F135
)
6
OUT5
Output TB Function select 7 (
F136
)
7
OUT6
Output TB Function select 8 (
F137
)
8
R2
Output TB Function select 9 (
F138
)
9
R3
Output TB Function select 10 (
F168
)
10
R4
Output TB Function select 11 (
F169
)
11 - 15
-
-
-
-
Bit
Function
0
1
Note