December 2000 © TOSHIBA TEC
1600/2000/2500 GENERAL PRECAUTIONS
GENERAL PRECAUTIONS REGARDING THE INSTALLATION AND
SERVICE FOR DP1600/2000/2500 SERIES
The installation and service should be done by a qualified service technician.
1. Transportation
•
When transporting/installing the copier, employ two persons and be sure to use the positions as
indicated below.
The copier is fairly heavy and weighs approximately 50 kg (110 lb), therefore pay full attention
when handling it.
2. Installation
•
Be sure to use a dedicated outlet with AC 115 or 120V/15A (220V, 230V, 240V/10A) or more for its
power source.
•
The copier must be grounded for safety.
Never ground it to a gas pipe or a water pipe.
•
Select a suitable place for installation.
Avoid excessive heat, high humidity, dust, vibration and direct sunlight.
•
Also provide proper ventilation as the copier emits a slight amount of ozone.
•
To insure adequate working space for the copying operation, keep a minimum clearance of 80
cm (32") on the left, 80 cm (32") on the right and 10 cm (4") in the rear.
•
After having installed the copier, be sure to push the carrying handles into the copier.
3. Service of Machines
•
Basically, be sure to turn the main switch off and unplug the power cord during service.
•
Be sure not to touch high-temperature sections such as the exposure lamp, the fuser unit, the
damp heater and their periphery.
•
Be sure not to touch high-voltage sections such as the chargers and the high-voltage transformer.
•
Be sure not to touch rotating/operating sections such as gears, belts, pulleys, fans, etc.
•
When servicing the machines with the main switch turned on, be sure not to touch live sections
and rotating/operating sections. Avoid exposure to laser radiation.
•
Use suitable measuring instruments and tools.