1600/2000/2500 ADJUSTMENT
1 - 70
December 2000 © TOSHIBA TEC
: Adjust value "YYY" so that the measurement values satisfy the values in
the following table.
Code
ADJUST MODE
MC =
(2) Operation
Note
When adjusting the high-voltage output, a measuring jig is required. (except the developer
bias measurement.)
Connect the digital testers as instructed in (1) and follow the procedure below to adjust the developer bias,
main charger, transfer, separation output.
<Keys used in operation>
<Display messages>
: Enter code
Measurement
value
Main
Charger
210
-637±5V
-674±5V
Developer
Bias
205
-430±5V
-460±5V
Transfer Charger (On the drum)
High
220
1372mV
±191mV
Center
221
1098mV
±146mV
1179mV
±193mV
Separation Charger (On the drum)
High
233
-553mV
±101mV
Center
234
-425mV
±51mV
Low
235
-300mV
±51mV
: Value "YYY" after adjustment is stored to SRAM.
: Return to other adjustment mode.
Power ON
0
5
Digital Keys
SET
Digital Keys
or
CANCEL
Power OFF
: code No.
: Current entried adjustment value
ADJUST MODE
MC = XXX
DT = YYY
START
or
SET
START
or
DP1600 series
DP2000/2500
series
Code
Measurement
value
DP1600 series
DP2000/2500
series