1600/2000/2500 ADJUSTMENT ITEMS
1 - 74
December 2000 © TOSHIBA TEC
3. Hold original glass stay to original glass and
tighten 2 screws.
Fig. 1-8-3
1.8 Adjusting the Scanner Section
1.8.1 Installing glass
(a) Installing ADF glass
To install new ADF glass, wipe off the mounting sur-
face and mount the glass by placing it at the posi-
tion shown right.
Fig. 1-8-1
(b) Installing original glass
Original glass should be installed in the following
manner:
1. Place the ADF glass by aligning with the posi-
tioning tab.
2. Hold original glass to the stopper and tighten 4
screws.
Fig. 1-8-2
ADF glass
Original
glass
Stopper
Tab
Screw
Original glass stay
Screw
Original glass
043-3
043-4
043-5