December 2000 © TOSHIBA TEC
10 - 7
1600/2000/2500 DRIVE SYSTEM
031-1
Fig. 10-3-4
Screw
Clamp
Main drive gear assembly
Harness
Connector
Screw
031-2
Fig. 10-3-5
01/09
16. Detach 2 connectors from the PWA.
17. Release the harness from inside the copier, re-
move 7 screws, and remove main drive gear
assembly.
Note:
When the main drive gear assembly is at-
tached, adjust it by referring to the Service
Handbook. (See chapter 1.9)
[B] Main moter
(DP1600 series)
1.
If a STP (KK-1600) is attached to the copier,
disconnect the power cable.
2.
Detach the manual pocket.
3.
Detach the toner cartridge and the process unit.
4.
Detach rear cover. (See Fig. 2-6-1)
5.
Detach 2 connectors form the PWA.
6.
Remove 3 screws and remove main motor.
7-1. If the main motor is without the flange to the
pulley, attach it in the reverse procedure.
Notes:
1. After attaching the main motor, rotate the
main motor to make sure that the cou-
pling of the process unit rotates.
2. Seeing from the gap of the main drive
gear cover assembly, confirm that the
timing belt is securely installed.
Screw
Pulley
Timing belt 176
Main motor
Connector
Summary of Contents for DP1600
Page 1: ...DIGITALPLAINPAPERCOPIER DP1600 2000 2500 File No 31100011 R0111216600 TTEC ...
Page 2: ...Copyright 2000 TOSHIBA TEC CORPORATION ...
Page 232: ...1600 2000 2500 PCB BOARD 16 2 December 2000 TOSHIBA TEC 16 2 PWA F RLY 16 02 01 ...
Page 233: ...December 2000 TOSHIBA TEC 16 3 1600 2000 2500 PC BOARD 16 3 PWA F PIF 16 03 01 ...
Page 237: ...17 WIRE HARNESS CONNECTION DIAGRAMS 17 1 ...
Page 264: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8842 JAPAN ...