1600/2000/2500 FUSER UNIT/PAPER EXIT UNIT
14 - 10
December 2000 © TOSHIBA TEC
Fig. 14-7-1
Groove
085
02/01
Fig. 14-7-1-1
Heater thermistor
harness
1
2
Rib
Heater lamp
harness
Screw
Fuser unit
Screw
Heater lamp
harness
Heater thermistor
harness
Heater lamp
harness
085-1
Note:
With the DP1600 series, after attaching the
fuser unit, confirm the continuity between
the screw fixed in the front side and main
frame with the multi-meter as shown in right.
3 -1
Screw
Fuser
Frame
- terminal
097-8
+ terminal
3 -2
Fig. 14-7-1-2
14.7 Disassembly and Replacement
[A] Fuser unit
1-1. If an ADU (MD-0101) and/or SFB (MY-1016)
are attached to the copier, detach it.
1-2. Open ADU (MD-0101) if it is attached.
2-1. Detach right cover R. (See Fig. 2-6-15)
2-2. Detach upper right cover R.
(See Fig. 2-6-15-1)
3.
Detach 2 connectors, remove 2 screws, and
remove fuser unit.
Note:
The fuser unit is to be attached by follow-
ing the procedures described below.
1. Be sure to pass the heater thermistor
harness through the groove of the fuser
unit. (See Fig. 14-7-1 1 )
2. Pass the heater lamp harness through
the space between the top and bottom
of the ribs. (See Fig. 14-7-1 2 )
3. Connect the heater lamp harness and
then connect the heater thermistor har-
ness. At this time, pass the heater lamp
harness through the right of the heater
thermistor harness and push it inside.
(See Fig. 14-7-1-1)
Summary of Contents for DP1600
Page 1: ...DIGITALPLAINPAPERCOPIER DP1600 2000 2500 File No 31100011 R0111216600 TTEC ...
Page 2: ...Copyright 2000 TOSHIBA TEC CORPORATION ...
Page 232: ...1600 2000 2500 PCB BOARD 16 2 December 2000 TOSHIBA TEC 16 2 PWA F RLY 16 02 01 ...
Page 233: ...December 2000 TOSHIBA TEC 16 3 1600 2000 2500 PC BOARD 16 3 PWA F PIF 16 03 01 ...
Page 237: ...17 WIRE HARNESS CONNECTION DIAGRAMS 17 1 ...
Page 264: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8842 JAPAN ...