1600/2000/2500 COPYING PROCESS
3 - 16
December 2000 © TOSHIBA TEC
[I] Magnetic roller/ Doctor blade
1. Remove the toner cartridge and the process
unit.
2. Detach the drum assembly. (See Fig. 3-4-2.)
3. Remove the timing belt 138.
01/11
Fig. 3-4-21
4. Remove 2 screws and detach the developer
gear cover.
Fig. 3-4-22
5. Remove one E-ring and detach the developer
drive gear 1 and washer.
6. Remove one E-ring and detach the washer and
developer drive gear 2.
7. Detach the magnetic roller drive gear.
Note:
Apply 0.1g of the grease (X5-6020
GREASE) to the gear teeth of the devel-
oper drive gear 1 (except the part used for
hooking the timing belt 138), developer drive
gear 2 and magnetic roller drive gear.
Fig. 3-4-23
Developer
assembly
Timing belt 138
3-4-21
Developer
assembly
Screw
Developer gear
cover
3-4-22
Developer
drive gear 2
Washer
E-ring
E-ring
Developer
drive gear 1
Washer
Magnetic roller
drive gear
Developer
assembly
3-4-23
8. Release 2 hooks and detach the magnetic roller
guide.
Fig. 3-4-24
3-4-24
Developer
assembly
Magnetic roller
guide
Summary of Contents for DP1600
Page 1: ...DIGITALPLAINPAPERCOPIER DP1600 2000 2500 File No 31100011 R0111216600 TTEC ...
Page 2: ...Copyright 2000 TOSHIBA TEC CORPORATION ...
Page 232: ...1600 2000 2500 PCB BOARD 16 2 December 2000 TOSHIBA TEC 16 2 PWA F RLY 16 02 01 ...
Page 233: ...December 2000 TOSHIBA TEC 16 3 1600 2000 2500 PC BOARD 16 3 PWA F PIF 16 03 01 ...
Page 237: ...17 WIRE HARNESS CONNECTION DIAGRAMS 17 1 ...
Page 264: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8842 JAPAN ...