DP4500/3500 TROUBLESHOOTING
5 - 24
December 2000 © TOSHIBA TEC
Is the ADU motor working? (Perform the output check in the test mode: 03-110/160)
NO
1. Check if the connector of the ADU motor is disconnected.
2. Check if any of the connectors CN211, CN212 and CN215 on the ADU board is
disconnected.
3. Check if the connector J316 on the LGC board is disconnected.
4. Check if the connector pins are disconnected and the harnesses are open-circuited.
5. Check if the conductor patterns on the ADU board and LGC board are short- or
open-circuited.
6. Replace the ADU exit sensor.
7. Replace the ADU board.
8. Replace the LGC board.
YES
Check the rollers in the ADU and the exit roller of the main unit. Replace them if they are worn out.
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼