December 2000 © TOSHIBA TEC
5 - 83
DP4500/3500 TROUBLESHOOTING
[CC2] Communication error between finisher and saddle stitcher
MJ-1012/1013
Is the problem solved by turning OFF and ON the power switch of the copier?
YES
END
NO
Is the wiring between the finisher controller PC board and the saddle stitcher controller PC board
connected?
YES
Connect the wiring.
NO
Measure the voltage between J3-2 (+) and J3-1 (-) on the finisher controller PC board. Is it DC 24V?
NO
Replace the finisher controller PC board.
YES
Replace the saddle stitcher controller PC board.
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼