December 2000 © TOSHIBA TEC
2 - 35
DP4500/3500 ADJUSTMENT
(2) Adjustment of the magnification ratio of the lens
Notes: 1. Perform magnification ratio adjustment of
the lens only when the lens unit has been
removed or is to be replaced.
2. Before making this adjustment, check
that the primary scanning reproduction
ratio of the printer is correct.
Feeding direction
Copied ruler
Actual ruler
a. Place a ruler on the original glass and make a copy on a A4(LT)-sized paper at a 100% reproduction
ratio.
b.
Compare the copied ruler with the actual ruler to see the difference in size.
c. Make adjustment following the procedure below, so as to make the distance between each mark on the
rulers match.
Note: After this adjustment is finished, be sure to perform the “deviation adjustment of the scanner primary
scanning start position”.
<Adjustment procedure>
1. Remove the original glass and lens cover.
2. Loosen the 2 screws fixing the lens unit.
Marks
Rear side
Front side