e-STUDIO160/200/250 SCANNER
7 - 30
December 2002 TOSHIBA TEC
Fig. 7-8-36
Fig. 7-8-37
Connector
065-11
Scanner thermostat
Screw
065-12
[L] Scanner thermostat
(SAD/ASD/AUD/CND models)
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, open it.
2. Remove original glass. (See Fig. 7-8-7)
3. Remove the blind plate.
(See Fig. 7-8-16 and 7-8-17)
4. Detach 2 connectors.
5. Remove 2 screws and remove the scanner
thermostat.
Screw
Hook
Damp heater plate
065-9
[M] Damp heater
(SAD/ASD/AUD/CND models)
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, open it.
2. Remove original glass. (See Fig. 7-8-7)
3. Move carriage 1 to around the center.
(See Fig. 7-8-22)
4. Peel off the sheet. (e-STUDIO160 series)
5. Remove the screw, release the hook, and de-
tach the damp heater plate.
(e-STUDIO200/250 series)
Fig. 7-8-38
Sheet
065-13
e-STUDIO160 series
e-STUDIO200/250 series
Fig. 7-8-39