December 2002 TOSHIBA TEC
2 - 17
e-STUDIO160/200/250 OUTLINE OF THE MACHINE
(7) Heaters and lamps
(8) Transformers
Remarks
(A-1)
Function
PWA which generates high voltage power.
Symbol
HVPS
Name
PS-HVPS
High voltage power supply
unit
(9) Others
Remarks
(D-2)
(D-1)
(D-1)
(D-1)
(D-2)
(D-2)
Function
A light source lamp for document scanning.
Fixes toner to the paper.
(NAD/SAD models)
Fixes toner to the paper.
(ASD/AUD/CND/MJD models)
Dehumidifies the inside of the scanner.
(SAD model)
Dehumidifies the inside of the scanner.
(ASD/AUD/CND models)
Removes residual charge on the drum
surface. (In Process unit)
Symbol
EXP
HL1
HL2
HL3
DH1
DLE
Name
EXPO-LAMP
Exposure lamp
U900-HL
Heater lamp U900
E400-HL
Heater lamp E400
E500-HL
Heater lamp E500
SCN-DH-115
Scanner dump heater
SCN-DH-230
Scanner dump heater
PWA-F-DLE
Discharge LED PWA
Remarks
(A-2)
(A-2)
(A-1)
Function
PWA which generates DC power.
(NAD/SAD models)
PWA which generates DC power.
(ASD/AUD/CND/MJD models)
PWA which relays AC power to each damp
heater.
(ASD/AUD/CND/SAD models)
Symbol
LVPS
FUS
Name
PS-LVPS-US
Switching power supply unit
PS-LVPS-EU
Switching power supply unit
PWA-F-FUS
Fuser relay PWA
Summary of Contents for e-studio 160
Page 2: ... 2002 TOSHIBA TEC CORPORATION All rights reserved ...
Page 223: ...e STUDIO160 200 250 PCB BOARD 16 2 December 2002 TOSHIBA TEC 16 2 PWA F RLY 16 02 01 ...
Page 224: ...December 2002 TOSHIBA TEC 16 3 e STUDIO160 200 250 PC BOARD 16 3 PWA F PIF 16 03 01 ...
Page 226: ...December 2002 TOSHIBA TEC 16 5 e STUDIO160 200 250 PC BOARD 16 6 PWA F SLG 16 06 01 ...
Page 228: ...17 WIRE HARNESS CONNECTION DIAGRAMS 17 1 ...
Page 255: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8842 JAPAN ...