e-STUDIO160/200/250 COPYING PROCESS
3 - 10
December 2002 TOSHIBA TEC
Fig. 3-4-1
3-4-33
[B] Main charger wire/ Main charger grid
1. Remove the toner cartridge and the process
unit.
2. Remove 4 screws and detach the drum assem-
bly.
Fig. 3-4-2
3. Remove 2 screws and detach the DLE PWA
assembly.
Fig. 3-4-3
3-4-34
3-4-03
Spring
Separation claw
Drum assembly
Screw
Screw
Screw
Screw
DLE PWA assembly
[A] Separation claw
1. Remove the toner cartridge and the process
unit.
2. Detach the separation claw.
Note:
Be careful not to be injured by the edges of
the separation claw and star wheel.
3.4
Disassembly and Replacement
When disassembling the process unit, pay special attention not to damage the drum and magnetic roller.
Also, be careful not to be injured by the edges of the parts.