December 2002 TOSHIBA TEC
4 - 3
e-STUDIO160/200/250 COPIER OPERATION
4) Weekly Timer
The Weekly Timer function controls the Sleep mode for each day of the week. You can program this
function on the panel and determine the ON/OFF time (in minutes) for each day of the week from Sunday
through Saturday (one week). The Weekly Timer function itself can also be turned ON or OFF. Even if the
time is set, the Weekly Timer function does not work unless the function is ON.
4.2.3 Automatic feed copying using the START key
1) Press the START key.
2) The polygon motor and main motor start operation. At the same time, development bias positive
output begins and the discharge LED turns ON. The exhaust fan begins to turn at high speed. Paper
separation bias output turns ON (Low).
3) After the main motor reaches a constant speed, charge output begins.
4) A specified time after the charge output has begun, the development bias output is switched to nega-
tive. At the same time, paper separation bias output is turned OFF.
5) After the polygon motor has reached a constant speed, the laser is forced to turn OFF for synchroniz-
ing the UFE.
6) Paper pickup begins.
7) A required time after the feed sensor has turned ON, registration roller drive begins.
8) Laser exposure begins. At the same time, paper separation bias output is turned ON (High).
9) Transfer output turns ON (High). When a specified time has elapsed, the transfer output is switched to
Mid.
10) Transfer guide bias output turns ON. At the same time, the paper separation bias output is switched to
Low. When a specified time has elapsed, the paper separation bias is switched to Mid.
11) In a specified time after the feed sensor has turned OFF, the paper separation bias output is switched
to Low.
12) In a specified time after the feed sensor has turned OFF, the registration roller drive is stopped.
13) In a specified time after the paper separation bias output has been switched to Low, the transfer output
is switched to OFF.
14) The paper separation bias output is switched to High in a specitied period of time after the transfer
output is turned OFF.
15) When a specified time has elapsed, the transfer guide bias is turned OFF.
16) In a specified time after the exit sensor has turned OFF, the charge is turned OFF and the paper
separation bias output switched to OFF at the same time.
17) The polygon motor and main motor turn OFF.
18) The development bias output is reversed and paper separation bias output is turned ON (Low). At the
same time, the laser enable output is turned OFF.
19) The development bias output is turned OFF after a specified time, and the paper separation bias
output and the discharge LED output are turned OFF at the same time.
Summary of Contents for e-studio 160
Page 2: ... 2002 TOSHIBA TEC CORPORATION All rights reserved ...
Page 223: ...e STUDIO160 200 250 PCB BOARD 16 2 December 2002 TOSHIBA TEC 16 2 PWA F RLY 16 02 01 ...
Page 224: ...December 2002 TOSHIBA TEC 16 3 e STUDIO160 200 250 PC BOARD 16 3 PWA F PIF 16 03 01 ...
Page 226: ...December 2002 TOSHIBA TEC 16 5 e STUDIO160 200 250 PC BOARD 16 6 PWA F SLG 16 06 01 ...
Page 228: ...17 WIRE HARNESS CONNECTION DIAGRAMS 17 1 ...
Page 255: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8842 JAPAN ...