7-9
e-STUDIO161 SIMULATIONS
43
01
Fusing temperature setting
(During normal copy)
When the simulation is terminated, the current set value is displayed. When the [%] key is pressed,
the setting is changed. When the [START] key is pressed, the set content is written into the EEPROM
and the machine goes into the sub code input standby mode.
12
Standby mode fusing fan rotation
setting
When this simulation is executed, the current set code number is displayed. Enter the desired code
number and press the [START] key to set the code number.
13
Fusing paper interval control allow/
inhibit setting
Used to set the paper feed timing of 21st and later page to A3 or WLT when multi copying or printing
paper of narrow width. (A3 or WLT depends on the destination.)
When this simulation is executed, the currently set code number is displayed. Enter a desired code
number and press the [START] key, and the entered code number is written into the EEPROM and
the machine goes into the sub code entry standby mode.
<Applicable paper>
1) Cassette paper feed: A4R, B5R, 8-1/2" X 14", 8-1/2" X 13", 8-1/2" X 11", A5, INV
2) Manual paper feed: A4R, B5R, 8-1/2" X 14", 8-1/2" X 13", 8-1/2" X 11", A5, INV,16KR
*
A5 size for manual paper feed is valid only for EX Japan AB series.
44
34
Transfer current setting
Used to set the transfer current for the front surface and that for the back surface. When this
simulation is executed, the current set value is displayed on the 7-seg display. Select the set value
with the zoom (Up/Down) keys and press the [START] key, and the set content is written into the
EEPROM and the machine goes into the sub code input standby mode. Press the [Mode select] key
to select each setting mode. At that time, the setup content is written into the EEPROM.
The set range is 90uA ~ 360uA in the increment of 10uA.
*
Small size paper must be Letter R (A4R) or smaller.
*
For the special size of tray, use the normal size width.
40
Setting of rotation time before
toner supply
Used to set the time interval between start of rotation (ready) of the main motor and start of toner
supply in previous rotation after supplying the power. [1] ~ [99] (Default [8], unit: sec)
46
01
Copy density adjustment (300dpi)
Used to set the copy density for each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading are operated, and the current set value is
displayed in two digits. (Default [50])
*
The density LED is not lighted.
Change the set value and press the [START] key, and a copy is made according to the set value.
The greater the set value is, the darker the density is, and vise versa. In this case, only a copy at Exp.
3 can be made. When, however, the density is set darker, Exp.1 and Exp. 5 become darker, too.
If the dentistry is set lighter, Exp. 1 and Exp. 5 become lighter, too. To select a desired copy mode,
press the [Copy mode select] key. The selected copy mode set value is displayed on the copy
quantity display. (Adjustment range: 1 ~ 99)
Main
code
Sub
code
Contents
Details of operation
Set temperature (°C)
Set temperature (°C)
160
165
170 * Default
175
180
185
190
195
200
Code number
Setting
0
1
Low speed rotation *Default
High speed rotation
Code number
Setting
0
1
Inhibit * Default
Allow
Display lamp
Setting mode
AE mode lamp
AE mode lamp & PHOTO mode lamp
AE & TEXT & PHOTO mode lamps
Normal size width: Front
Small size width: Front
Manual paper feed
Display lamp
Copy mode
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
TEXT mode lamp & PHOTO mode lamp
AE mode lamp & PHOTO mode lamp
AE mode (300dpi)
TEXT mode (300dpi)
PHOTO mode
TS mode (TEXT) (300dpi)
TS mode (AE) (300dpi)
[07]SIMULATIONS.fm 9 ページ 2004年1月9日 金曜日 午後1時20分