e-STUDIO161 TROUBLE CODE LIST
F5
02
Content
Copy lamp lighting abnormality
Detail
The copy lamp does not turn on.
Cause
Copy lamp abnormality
Copy lamp harness abnormality
CCD PWB harness abnormality.
Check
and
remedy
Use SIM 5-3 to check the copy lamp
operations.
When the copy lamp lights up.
Check the harness and the connector between
the CCD unit and the MCU PWB.
When the copy lamp does not light up.
Check the harness and the connector between
the copy lamp unit and the MCU PWB.
Replace the copy lamp unit.
Replace the MCU PWB. "
H2
00
Content
Thermistor open
Detail
The thermistor is open.
The fusing unit is not installed.
Cause
Thermistor abnormality
Control PWB abnormality
Fusing section connector disconnection
The fusing unit is not installed.
Check
and
remedy
Check the harness and the connector between
the thermistor and the PWB.
Use SIM 14 to clear the self diagnostic display.
H3
00
Content
Heat roller high temperature detection
Detail
The fusing temperature exceeds 240C°.
Cause
Thermistor abnormality
Control PWB abnormality
Fusing section connector disconnection.
Check
and
remedy
Use SIM 5-02 to check the heater lamp blinking
operation.
When the lamp blinks normally.
Check the thermistor and its harness.
Check the thermistor input circuit on the control
PWB.
When the lamp keeps ON.
Check the power PWB and the lamp control
circuit on the MCU PWB.
Use SIM 14 to clear the self diagnostic display.
H4
00
Content
Heat roller low temperature detection
Detail
When the fusing temperature is lower than
150C° after 55sec from the start of warming
up.
When the warming up complete temperature is
not reached in 30sec from reaching 150C°.
When the fusing temperature is lower than
100C° after 20sec from ready start.
When the fusing temperature is lower than
145C° when printing."
Cause
Thermistor abnormality
Heater lamp abnormality
Thermostat abnormality
Control PWB abnormality
Check
and
remedy
Use SIM 5-02 to check the heater lamp blinking
operation.
When the lamp blinks normally.
Check the thermistor and its harness.
Check the thermistor input circuit on the control
PWB.
When the lamp does not light up.
Check for disconnection of the heater lamp and
the thermostat. Check the interlock switch.
Check the power PWB and the lamp control
circuit on the MCU PWB.
Use SIM 14 to clear the self diagnostic display.
Main
code
Sub
code
Details of trouble
L1
00
Content
Scanner feed trouble
Detail
The scanner does not complete feeding in the
specified time.
Cause
Mirror unit abnormality
The scanner wire is disconnected.
The origin detection sensor abnormality
Mirror motor harness abnormality
Check
and
remedy
Use SIM 1-1 to check the mirror reciprocating
operations.
When the mirror does not feed.
Check for disconnection of the scanner wire.
Check the harness and the connector between
the mirror motor and the MCU PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home position
sensor."
L3
00
Content
Scanner return trouble
Detail
The scanner does not complete returning in
the specified time.
The mirror is not in the home position when OC
copying is started with the mirror standby in the
home position.
Cause
Mirror unit abnormality
Scanner wire disconnection
Origin detection sensor abnormality
Mirror motor harness abnormality
Check
and
remedy
Use SIM 1-1 to check the mirror reciprocating
operations.
When the mirror does not return.
Check for disconnection of the scanner wire.
Check the harness and the connector between
the mirror motor and the MCU PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home position
sensor.
Main
code
Sub
code
Details of trouble