2-50
Service Manual
e-STUDIO 16P
Operator Panel Button Service Check
Button Service Check
FRU
Action
Operator Panel
Operator Panel Cable
Disconnect the operator panel from
the operator panel cable.
Check the continuity between J2–1
and J2–2 on the operator panel as
you press the operator panel button.
As the button is pressed, continuity
is present.
• If continuity is present, replace the
operator panel cable.
• If continuity is not present, replace
the operator panel.