1.TROUBLESHOOTING FOR THE HARDWARE
34 Clearing a Paper Misfeed
Fuser unit
Be careful not to let your fingers be caught between the equipment and the automatic duplexing unit cover.
This could injure you.
Do not touch the fuser unit or the metal portion around it.
Since they are very hot, you could be burned or the shock could cause you to get your hand injured in the machine.
1
Open the automatic duplexing unit cover on the right.
2
For e-STUDIO2020AC/2520AC and e-STUDIO2525AC/3025AC/3525AC/4525AC, press down the two
green fuser pressure release levers until they stop.
3
Open the transport guide holding the green knob and then release the misfed paper. Pull the
misfed paper up or down as shown in the illustrations depending on the position of the paper.
4
Remove the paper from the exit section.
3
2
1