e-STUDIO202S DISASSEMBLY AND ASSEMBLY 8 - 4
2) Set the charger cleaner to the transfer unit, and move it recip-
rocally a few times in the direction of the arrow shown in the
figure below.
F. Charger wire replacement
1) Remove the TC cover and remove the screw.
2) Remove the spring and remove the charger wire.
3) Install a new charger wire by reversing the procedures (1) and
(2).
At that time, be careful of the following items.
• The rest of the charger wire must be within 1.5mm. Refer to
Fig.1
• The spring hook section (charger wire winding section) must be
in the range of the projection section.
• Be careful not to twist the charger wire.
2. Operation panel section
A. List
B. Disassembly procedure
1) Open the side door, and Open the front cover.
2) Remove the screws (4 pcs.), the harness, and the operation
panel unit.
1)
2)
3)
4)
1mm
1.5mm
Fig.1
1)
1)
2)
3)
Charger wire
Protrusion
No.
Part name Ref.
1
Operation panel unit
2
Operation PWB
1)
2)
1)
1)
1)
2)
1)