e-STUDIO202S SIMULATION, TROUBLE CODES 10 - 4
06
01
Paper feed solenoid ON
(Operation/Procedure)
When the START key is pressed, the paper feed solenoid selected by the tray select key repeats ON (500ms) and OFF
(500ms) 20 times.
02
Resist solenoid ON
(Operation/Procedure)
When the START key is pressed, the resist solenoid (RRS) repeats ON (500ms) and OFF (500ms) 20 times.
07
01
Warm-up display and aging with jam
(Operation/Procedure)
1. When the simulation is executed, warming up is started.
2. Warm-up time is counted and displayed every second on the copy quantity display.
3. After completion of warm-up, the time count is stopped and the ready lamp is lighted.
4. Press the clear key to clear the warm-up time display, set the copy quantity, and press the START key, and the machine will
copy the set quantity repeatedly.
This simulation is canceled by turning off the power or executing any simulation which performs hardware reset.
06
Intermittent aging
(Operation/Procedure)
1. When the simulation is executed, warming up is started.
2. After completion of warm-up, the ready lamp is lighted.
3. Set the copy quantity and press the START key, and the machine will copy the set quantity repeatedly.
4. After 3 sec of the interval time from completion of copying the set quantity, the machine will resume copying.
5. The above operation 4 is repeated.
This simulation is canceled by turning off the power or executing any simulation which performs hardware reset.
08
Shift to copy with the warm-up display.
When the simulation code is entered, warming-up is started. The warming-up time is counted from 0 in the increment of 1 sec.
The operation during count-up process is as stated below.
When C key is pressed, the operation is terminated. (The 7-seg display indicates the sub code.)
Warming-up operation is continued.
After completion of warming-up, counting is terminated. (This is similar to SIM 07-01 without the aging function.
08
01
Developing bias
(Operation/Procedure)
When the START key is pressed, the developing bias is outputted for 30 sec.
02
Main charger (Grid high)
(Operation/Procedure)
When the START key is pressed, the main charger output is supplied for 30 sec in the grid voltage HIGH mode.
03
Grid voltage (Low)
(Operation/Procedure)
When the START key is pressed, the main charger output is supplied for 30 sec in the grid voltage LOW mode.
06
Transfer charger
(Operation/Procedure)
When the START key is pressed, the transfer charger output is supplied for 30 sec.
10
NONE Toner motor aging
(Operation/Procedure)
When the START key is pressed, the toner motor output is supplied for 30 sec.
14
NONE Cancel of troubles other than U2
(Operation/Procedure)
After canceling the trouble, the simulation is also automatically canceled.
16
NONE Cancel of U2 trouble
(Operation/Procedure)
1. When the START key is pressed, the EEPROM total counter check sum is rewritten and the trouble is canceled.
2. After canceling the trouble, the simulation is also automatically canceled.
20
01
Maintenance counter clear
When START key is pressed, the maintenance count value is cleared and "000,000" is displayed.
The value (000,000) is displayed on the 7seg in 3 digits for each.
21
01
Maintenance cycle setting
The currently set code of the maintenance cycle is displayed, and the newly set data are saved.
Enter the code number with UP/UP key and press START key. The entered value is saved and the display returns to the sub
code input standby state.
Main
code
Sub
code
Content
Code number
Setting
Remark
0
3,000 sheets
1
6,000 sheets
2
9,000 sheets
3
13,000 sheets
4
25,000 sheets
Default
5
Free (999,999 sheets)