e-STUDIO202S SIMULATION, TROUBLE CODES 10 - 9
43
04
Fusing temperature setting in multi copy
From the 20th sheet and later, the fusing temperature is changed over from the level set with SIM 43-1 to the level set with this
simulation.
When this simulation is executed, the currently set code number is displayed.
Enter the code number with UP/UP key and press START key. The entered value is saved and the display returns to the sub
code input standby state.
The exposure select key is used to select the mode. The set value of the selected mode is displayed on the 7seg.
∗
The cassette feed and the manual feed are controlled similarly.
09
Fusing control setting for postcard-size paper
When this simulation is executed, the currently set code number is displayed.
Enter the code number and press START key to save the setting.
11
Fusing temperature setting for postcard-size paper
When this simulation is executed, the current set value is displayed.
Press UP/UP key to select the setting, and press START key to write into the EEPROM. The display returns to the sub code
input standby mode.
14
Fusing start temperature setting
The fusing temperature when starting printing (first – second sheet) is set.
When this simulation is executed, the currently set code number is displayed.
When the code number is entered with UP/UP key and the START key is pressed, setting is changed over.
The exposure select key is used to select the mode. The set value of the selected mode is displayed on the 7seg.
∗
The cassette feed and the manual feed are controlled similarly.
Main
code
Sub
code
Content
Code number
Set temperature (°C)
0
165
1
170
2
175
3
180
4
185
5
190
Mode
Lamp ON
Default
Main cassette paper feed & 2nd cassette paper feed
AE mode lamp
3
Manual paper feed
TEXT mode lamp
3
Main cassette paper feed & 2nd cassette paper feed (small-size)
PHOTO mode lamp
1
Manual paper feed (small-size)
AE, TEXT mode lamp
1
Code number
Temperature shift (°C)
0
Cancel * Default
1
Setting
Code number
Temperature shift (°C)
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195 * Default
8
200
Code number
Set temperature (°C)
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195 (* Default)
8
200
Mode
Lamp ON
Main cassette paper feed & 2nd cassette paper feed
AE mode lamp
Manual paper feed
TEXT mode lamp