e-STUDIO202S SIMULATION, TROUBLE CODES 10 - 10
43
15
Postcard size paper fusing control cycle sync setting
When this simulation is executed, the currently set code number is displayed.
Change the setting with UP/UP key, and press START key to write the setting to the EEPROM. (Setting range: 0 – 20, default:
0)
∗
When set to "0," the setting is canceled and the fusing temperature control and the paper pass timing are not synchronized.
The conventional control (control same as the other paper) is performed.
∗
When set to "1" – "20," the postcard pass is synchronized with the fusing temperature control cycle, providing stable fusing
performance. However, CPM is reduced.
∗
When set to "1" – "20," if "Set value x 0.5°C + Temperature control level," the fusing heater lamp is turned OFF.
46
01
Copy density adjustment (300dpi)
Used to set the copy density in each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading operations are performed and the current setup is displayed in two
digits (default: 50).
Change the setup value with the copy quantity keys. Press the START key and a copy is made according to the new setup.
The greater the setup value is, the darker the copy is. The smaller the setup value is, the brighter the copy is. Only EXP.3 copy
is made in this simulation. When set to a darker level, Exp.1 and Exp.5 copies also become darker. When set to a brighter
level, Exp.1 and Exp.5 copies also become brighter. Press the CLEAR key to save the setup and exit from the simulation
mode.
The exposure select key is used to select the mode. The set value of the selected mode is displayed on the 7seg.
(adjustment range: 1 – 99)
02
Copy density adjustment (600dpi)
Used to set the copy density in each mode.
(Operation/Procedure)
When this simulation is executed, the machine performs warm-up and shading, and the current setup value is displayed in two
digits. (Default: 50)
Use the copy quantity key to change the setup value, and press the START key to make a copy with the new setup.
The greater the setup value is, the darker the copy is, and vise versa. Only EXP.3 copy is made. If it is set to a darker density,
EXP.1 and EXP.5 copies also become darker. If it is set to a brighter density, they also become brighter.
When the CLEAR key is pressed, the entered setup value is saved and the simulation is terminated.
The exposure select key is used to select the mode. The set value of the selected mode is displayed on the 7seg.
(adjustment range: 1 – 99)
Main
code
Sub
code
Content
Code number
Sync setting
Fusing heater lamp OFF timing temperature
0
Cancel
– (* Default)
1
Setting
+0.5°C
:
:
6
+3.0°C
:
:
20
+10.0°C
Copy mode
Display lamp
AE mode (300dpi)
AE mode lamp
TEXT mode (300dpi)
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT) (300dpi)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE) (300dpi)
AE mode lamp & PHOTO mode lamp
Copy mode
Display lamp
AE mode (600dpi)
AE mode lamp
TEXT mode (600dpi)
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT) (600dpi)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE) (600dpi)
AE mode lamp & PHOTO mode lamp