e-STUDIO202S SIMULATION, TROUBLE CODES 10 - 11
46
18
Image contrast adjustment (300dpi)
Used to set the image contrast in each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading operations are performed and the current setup value is displayed in
two digits. (Default: 50)
Change the setup value with the copy quantity keys. Press the START key and a copy is made according to the new setup.
The greater the setup value is, the higher the contrast is. The smaller the setup value is, the lower the contrast is. Though only
EXP.3 copy is made in this simulation, the contrast levels in EXP.1 and EXP.5 are also changed. Press the CLEAR key to save
the setup and exit from the simulation mode.
The exposure select key is used to select the mode. The set value of the selected mode is displayed on the 7seg.
(adjustment range: 1 – 99)
19
Exposure mode setup
<
γ
table setup or AE operation mode setup>
When this simulation is executed, the current setup of the gamma table code number is displayed. Enter the code number
corresponding to desired gamma table, and press the START key or the exposure select key to enable the setup.
When the exposure select key is pressed during setup of the gamma table, the mode is switched to the AE operation setup
mode and the current setup of the AE operation mode code number is displayed. (Default: 0) Enter the code number
corresponding to your desired AE operation mode, and press the START key or the exposure select key to switch the setup.
(When the exposure select key is pressed, the mode is returned to the gamma table setup mode.)
<PHOTO image process setting>
When the exposure select key is pressed in the AE operation mode setting, the mode is changed to the PHOTO image
process setting and the currently set code number of the PHOTO image process setting is displayed. (Default: 0)
When the code number corresponding to the desired Photo image process setting is entered and the exposure select key is
pressed, the mode is changed over.
20
ADF exposure correction <ADF model only>
Used to adjust the exposure correction quantity in the ADF mode by adjusting the differential of Vref voltage for the OC mode.
(Operating procedure)
When this simulation is executed, the current setup is displayed. Enter the adjustment value and press the START key to
enable the setup and make a copy.
When the CLEAR key is pressed, the entered value is saved and the simulation mode is terminated.
∗
The greater the value is the darker the exposure is.
The smaller the value is, the brighter the exposure is.
Main
code
Sub
code
Content
Copy mode
Display lamp
AE mode (300dpi)
AE mode lamp
TEXT mode (300dpi)
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT) (300dpi)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE) (300dpi)
AE mode lamp & PHOTO mode lamp
Code number
γ
table
1
Image quality priority mode
2
Toner consumption priority mode * Default
Code number
AE operation mode
0
Fixed process * Default
1
Real time process
Mode
Code number
Setting content
Display lamp
Remark
γ
1
Image priority mode
OFF
Default : NAD, ARD
2
Toner consumption priority mode
Default : BRAD, ASD, ASU, MJD
AE
0
Lead edge stop
AE ON
Default
1
Real time process
PHOTO
1
Error diffusion process
PHOTO ON
Default
2
Dither process
Mode
Display lamp
ADF
TEXT mode lamp