© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 81
2
931
Image
Density
adjustment
Fine adjust-
ment of "man-
ual density"/
Center value
Custom
Mode 1
PPC
128
<0-255>
SYS
When the value
increases, the image of
the center step
becomes darker.
1
932
Image
Custom
Mode 2
PPC
128
<0-255>
SYS
1
933
Image
Custom
Mode 3
PPC
128
<0-255>
SYS
1
934
Image
Density
adjustment
Fine adjust-
ment of "man-
ual density"/
Light step
value
Custom
Mode 1
PPC
20
<0-255>
SYS
When the value
increases, the image of
the "light" step density
becomes lighter.
1
935
Custom
Mode 2
PPC
20
<0-255>
SYS
1
936
Custom
Mode 3
PPC
20
<0-255>
SYS
1
937
Image
Density
adjustment
Fine adjust-
ment of "man-
ual density"/
Dark step
value
Custom
Mode 1
PPC
20
<0-255>
SYS
When the value
increases, the image of
the "Dark" step density
becomes lighter.
1
938
Custom
Mode 2
PPC
20
<0-255>
SYS
1
939
Custom
Mode 3
PPC
20
<0-255>
SYS
1
940
Image
Density
adjustment
Fine adjust-
ment of "auto-
matic density"
Custom
Mode 1
PPC
128
<0-255>
SYS
When the value
increases, the image
becomes darker.
1
941
Custom
Mode 2
PPC
128
<0-255>
SYS
1
942
Custom
Mode 3
PPC
128
<0-255>
SYS
1
943
Image
Gamma data
slope adjust-
ment
Custom
Mode 1
PPC
0
<0-99>
SYS
One’s place:
0: Equivalent to the set
value 5
1 to 9: Select the slope
of Gammacurve (The
larger the value is, the
larger the slope
becomes.)
Ten’s place:
0: Equivalent to the set
value 5
1 to 9: Select the slope
of low density (The
smaller the value is, the
darker the background
becomes.)
00: Use default value
1
944
Custom
Mode 2
PPC
0
<0-99>
SYS
1
945
Custom
Mode 3
PPC
0
<0-99>
SYS
1
976
Mainte-
nance
Equipment number (serial
number) entry
ALL
-
SYS
When this adjustment
is performed with this
code, the setting code
(08-995) is also per-
formed automatically
(10 digits)
1
Adjustment mode (05) <e-STUDIO352/353/452/453>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
07/11