ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 84
Procedure 14
Notes:
1. The digit after the hyphen in “Code” of the following table is a sub code.
2. e-STUDIO350/450:
In "RAM", the NVRAM of the board in which the data of each code is stored is indicated.
"M" stands for the LGC board, "SYS" and "UTY" stands for the SYS board and "NIC"
stands for the NIC board.
Setting mode (08) <e-STUDIO350/450>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
200
General
Date and time setting
ALL
-
<13 dig-
its>
-
Year/month/date/day/
hour/minute/second
Example:
03 07 0 13 13 27 48
“Day” - “0” is for “Sun-
day”. Proceeds Monday
through Saturday from
“1” to “6”.
5
201
General
Destination selection
ALL
EUR: 0
UC: 1
JPN: 2
<0-2>
M
0: EUR
1: UC
2: JPN
1
202
User
interface
Counter installed externally
ALL
0
<0-3>
M
0: No external counter
1: Coin controller
2: Copy key card
(This value is valid
only when “2” is set
to 08-201.)
3: Key copy counter
1
203
General
Line adjustment mode
ALL
0
<0-1>
M
0: For factory ship-
ment
1: For line
*
Field: “0” must be
selected
1
204
User
interface
Auto-clear timer setting
ALL
3
<0-10>
SYS
Timer to return the
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10:
Set number x 15
sec.
1
[0][8]
[POWER]
[POWER]
OFF/ON
(Exit)
[Digital key]
(Code)
[Digital key]
(Sub-code)
[CLEAR]
(Corrects value)
[START]
[START]
[CANCEL]
[ENTER]
or
[INTERRUPT]
Adjustment value
cannot be changed