e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 112
672
General
Initialization of department
management information
-
-
SYS
Initializing of the depart-
ment management
information
*
Key in the code and
press the [INITIAL-
IZE] button to per-
form the
initialization.
If the area storing
the department
management infor-
mation is destroyed
for some reason,
“Enter Department
Code” is displayed
on the control panel
even if the depart-
ment management
function is not set
on. In this case, ini-
tialize the area with
this code. This area
is normally initial-
ized at the factory.
3
673
General
Trial period setting
ALL
254
<1-60>
SYS
Sets the trial period
from 1 to 60 days. This
setting is effective only
when the default value
is "254". Once the
default value is set, this
value is only used for a
reference.
1
678
General
Setting of banner advertis-
ing display
ALL
0
<0-1>
SYS
Sets whether or not dis-
playing the banner
advertising. The setting
contents of 08-679 and
08-680 are displayed at
the time display section
on the right top of the
screen. When both are
set, each content is dis-
played alternately.
0: Not displayed
1: Displayed
1
679
General
Banner advertising display
1
ALL
-
SYS
Maximum 27 letters
(one-byte character)
11
680
General
Banner advertising display
2
ALL
-
SYS
Maximum 27 letters
(one-byte character)
11
681
General
Display of [BANNER MES-
SAGE] button
ALL
0
<0-1>
SYS
0: Not displayed
1: Displayed
*
This button enables
the entry of “Banner
advertising display 1
(08-679)” and “Ban-
ner advertising dis-
play 2 (08-680)” on
the control panel.
1
682
Use
interface
Offsetting between jobs
ALL
1
<0-1>
SYS
0: Invalid
1: Valid
1
Setting mode (08) <e-STUDIO350/450>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e