e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 132
1422
Data
over-
write kit
HDD data overwriting type
setting
ALL
3
<0-4>
SYS
HDD data is cleared by
overwriting the type of
value set in this code.
(This setting is enabled
only when the GP-1050
is installed.)
0: "00" overwriting only
1: "FF" overwriting
only
2: Random number
overwriting only
3: "00" + "FF" + ran-
dom number over-
writing (validation
ON)
4: "00" + "FF" + ran-
dom number over-
writing (validation
OFF)
1
1424
Data
over-
write kit
HDD data clearing type
setting (forcible clearing)
ALL
3
<0-4>
SYS
HDD data is cleared by
overwriting the type of
value set in this code.
(This setting is enabled
only when the GP-1050
is installed.)
0: "00" overwriting only
1: "FF" overwriting
only
2: Random number
overwriting only
3: "00" + "FF" + ran-
dom number over-
writing (validation
ON)
4: "00" + "FF" + ran-
dom number over-
writing (validation
OFF)
1
1426
Data
over-
write kit
Forcible HDD data clearing
ALL
-
-
HDD data is cleared in
the procedure set in 08-
1424.
*
This setting is
enabled only when
the GP-1050 is
installed.
3
1427
Data
over-
write kit
Forcible NVRAM data all
clearing
ALL
-
-
When this code is per-
formed, the equipment
cannot be started up.
*
This setting is
enabled only when
the GP-1050 is
installed.
3
1428
Data
over-
write kit
Forcible SRAM backup
data all clearing
ALL
-
-
When this code is per-
formed, the equipment
cannot be started up.
*
This setting is
enabled only when
the GP-1050 is
installed.
3
Setting mode (08) <e-STUDIO350/450>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
05/05