e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 164
399
Laser
Accumulated time of polyg-
onal motor at normal rota-
tion
ALL
0
<8 digits>
M
Accumulates the time
the polygonal motor has
rotated at normal rota-
tion.
2
400
Fuser
Fuser unit error status
counter
ALL
0
<0-19>
M
0: No error
1: C411(Once)
2: C410(consecutively
occurred)
3: -
4: -
5: C440 6: C450
7: C440 8: C450
9: C440 10: C470
11: C470 12: C480
13: C480 14: C470
15: C480 16: C490
17: C470 18: C480
19: C490
1
409
Fuser
Fuser roller temperature at
a energy saver mode
(Center thermistor)
ALL
0
<0-13>
M
0: OFF 1: 40°C
2: 50°C 3: 60°C
4: 70°C 5: 80°C
6: 90°C 7: 100°C
8: 110°C 9: 120°C
10: 130°C 11: 140°C
12: 150°C 13: 160°C
1
410
Fuser
Fuser roller temperature
during printing (Center
thermistor/Plain paper)
ALL
12
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C 11: 195°C
12: 200°C 13: 205°C
14: 210°C
1
411
Fuser
Fuser roller temperature on
standby (Center ther-
mistor)
ALL
12
<0-12>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C 11: 195°C
12: 200°C
1
412
Fuser
Fuser roller temperature
during printing
(Center thermistor/Thick
paper 3)
ALL
12
<0-14>
M
1: 140°C 1: 145°C
3: 150°C 4: 155°C
5: 160°C 6: 165°C
7: 170°C 8: 175°C
9: 180°C 10: 185°C
11: 190°C 12: 195°C
13: 200°C 14: 210°C
1
413
Fuser
Fuser roller temperature
during printing
(Center thermistor/Thick
paper 1)
ALL
12
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C 11: 195°C
12: 200°C 13: 210°C
1
414
Devel-
oper
Toner density correction-
setting
ALL
0
<0-8>
M
0: Invalid
1: +3bit
2: +6bit
3: +9bit
4: +12bit
5: -3bit
6: -6bit
7: -9bit
8: -12bit
1
Setting mode (08) <e-STUDIO352/353/452/453>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
07/11