© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 179
2
710
Mainte-
nance
Short time interval setting
of recovery from Emer-
gency Mode
ALL
24
<1-48>
SYS
Sets the time interval to
recover from the Emer-
gency Mode to the Nor-
mal Mode.
(Unit: Hour)
1
711
Mainte-
nance
Short time interval setting
of Emergency Mode
ALL
60
<30-360>
SYS
Unit: Minute
1
715
Mainte-
nance
Remote-controlled service
periodical polling timing
(Hour/Hour/Minute/Minute)
ALL
1230
SYS
0 (0:00) to 2359 (23:59)
1
716
Mainte-
nance
Remote-controlled service
Writing data of self-diag-
nostic code
ALL
0
<0-1>
SYS
0: Prohibited
1: Accepted
1
717
Mainte-
nance
Remote-controlled service
response waiting time
(Timeout)
ALL
3
<1-30>
SYS
Unit: Minute
1
718
Mainte-
nance
Remote-controlled service
initial registration
ALL
0
<0-3>
SYS
0: OFF
1: Start
2: Only certification is
scanned
3: Sattelite communi-
cation starts
1
719
Mainte-
nance
Remote-controlled service
tentative password
ALL
-
SYS
Maximum 10 letters
11
720
Mainte-
nance
Status of remote-con-
trolled service initial regis-
tration (Display only)
ALL
0
<0-1>
SYS
0: Not registered
1: Registered
2
721
Mainte-
nance
Service center call function
ALL
2
<0-2>
SYS
0: OFF
1: Notifies all service
calls
2: Notifies all but
paper jams
1
723
Mainte-
nance
Service center call HTTP
server URL setting
ALL
-
SYS
Maximum 256 letters
11
726
Mainte-
nance
HTTP proxy setting
ALL
1
<0-1>
SYS
0: Valid
1: Invalid
1
727
Mainte-
nance
HTTP proxy IP address
setting
ALL
-
SYS
000.000.000.000 -
255.255.255.255
(Default value
000.000.000.000)
11
728
Mainte-
nance
HTTP proxy port number
setting
ALL
0
<0-
65535>
SYS
1
729
Mainte-
nance
HTTP proxy ID setting
ALL
-
SYS
Maximum 30 letters
11
730
Mainte-
nance
HTTP proxy password set-
ting
ALL
-
SYS
Maximum 30 letters
11
731
Mainte-
nance
HTTP proxy panel display
ALL
1
<0-1>
SYS
0: Valid
1: Invalid
1
732
Mainte-
nance
(Remote)
Automatic ordering func-
tion of supplies
ALL
3
<0-3>
SYS
0: Ordered by FAX
1: Ordered by E-mail
2: Ordered by HTTP
3: OFF
1
733
Mainte-
nance
(Remote)
Automatic ordering func-
tion of supplies
FAX number
ALL
-
SYS
Maximum 32 digits
Enter hyphen with the
[Monitor/Pause] button
11
Setting mode (08) <e-STUDIO352/353/452/453>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
07/11