e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 212
1775
General
Card reader format infor-
mation -3
ALL
-
SYS
Security key
“KKKKKKKKKKKK” (12
digits) <hexadecimal
number> in the [Key
Information] of the [Sec-
tor Number] set in the
code 08-1773 should
be entered.
5
1776
General
Card authentication LDAP
server
ALL
0
<0-100>
SYS
LDAP server number
for the card authentica-
tion when a noncontact
IC card is used should
be set.
1
1777
General
Card authentication LDAP
search index
ALL
-
SYS
LDAP search index
when a noncontact IC
card is used is set.
11
1778
General
Period for locking the con-
trol panel when an incor-
rect administrator
password has been
entered 3 consecutive
times
ALL
1
<0-7>
SYS
0: 0 min.
1: 0.5 min. (30 sec.)
2: 1 min.
3: 3 min.
4: 5 min.
5: 10 min.
6: 15 min.
7: 30 min.
1
1779
Network
Default data saving direc-
tory of "Scan to File"
ALL
0
<0-2>
SYS
0: Local directory
1: REMOTE 1
2: REMOTE 2
1
1781-0
Network
Notification of
scan job
When job
completed
ALL
0
<0-1>
SYS
Sets the notification
method of scan job
completion.
0: Invalid
1: Valid
4
1781-1
On error
ALL
0
<0-1>
SYS
4
1782
Network
File name format of "Save
as file" and Email transmis-
sion
ALL
0
<0-6>
SYS
Sets the naming
method of the file of
"Save as file" and Email
transmission.
0: [FileName]-[Data]-
[Page]
1: [FileName]-[Page]-
[Data]
2: [Data]-[FileName]-
[Page]
3: [Data]-[Page]-[File-
Name]
4: [Page]-[FileName]-
[Data]
5: [Page]-[Data]-[File-
Name]
6: [HostName]_[Data]-
[Page]
1
Setting mode (08) <e-STUDIO352/353/452/453>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
07/11