ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 248
5) Pixel counter confirmation
- Display on LCD screen
Whether or not to display the pixel counter on the LCD screen is selected (0: Displayed, 1: Not
displayed) in the setting mode (08-1504), and whether or not to display it at the service techni-
cian reference or toner cartridge reference is selected (0: Service technician reference, 1: Toner
cartridge reference) in the setting mode (08-1505).
The following screen is displayed when the buttons, [USER FUNCTIONS], [COUNTER] and
[PIXEL COUNTER] are pressed in this order after “Displayed” is selected with the code above
and the power is, as usual, turned ON.
The following screen is displayed when the toner cartridge reference is selected in the setting
mode (08-1505).
Fig. 2-6 Information screen of toner cartridge reference
The following screen is displayed when the service technician reference is selected in the setting
mode (08-1505).
Fig. 2-7 Information screen of service technician reference