ADJUSTMENT
3 - 2
(5) After a short time, the value B becomes stable and the display changes as follows.
(6) Check if the value B is within the range of 235 to 245 (the output voltage range of the auto-toner
sensor is 2.35 V to 2.45 V).
(7) If the value B is not within the range of 235 to 245, press the Up or Down button to adjust the
value manually.
Note:
Note:
The relation between the button and the values A and B is as follows.
(8) Press the [ENTER] or [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed.
(9) Turn the power OFF.
(10) Install the toner cartridge.
Button to be pressed
Value A
Value B
Up
Increased
Increased
Down
Decreased
Decreased
240%
B
A
128
200
A3
158
ADJUSTMENT MODE
100%
A
A3
TEST MODE
[ENTER]
or
[INTERRUPT]