© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
ADJUSTMENT
3 - 11
3
<Adjustment order>
[0] [5] [Power ON]
→
[1] ([3](05-445, 498) for duplexing)
→
[FAX]
A: 05-401 (Lower drawer, A3/LD)
→
200±0.5 mm (0.125 mm/step)
B: 05-411 (Lower drawer, A3/LD)
→
52±0.5 mm (0.05 mm/step)
→
Key in the same value for 05-410.
C: 05-421 (Lower drawer, A3/LD)
→
200±0.5 mm (0.125 mm/step)
D: 05-441 (Lower drawer, A3/LD), 440 (Upper drawer, A4/LT), 444 (PFP, A4/LT),
443 (LCF, A4/LT), 442 (Bypass feed, A4/LT), 445 (Duplexing, A3/LD)
→
52±0.5 mm (0.4 mm/step)
E: 05-498-0 (Lower drawer, A3/LD), 498-1 (Upper drawer, A4/LT)
→
52±0.5 mm (0.05 mm/step)
Remark:
When the adjustment (05-421) is performed, the same adjustment for FAX (05-422) is automati-
cally and consecutively performed.
04/09