© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
ADJUSTMENT
3 - 15
3
[C] Image position adjustment of the primary scanning direction
(1) While pressing [0] and [5] simultaneously, turn the power ON.
→
(Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
(3) Press [FAX] to make a copy at the mode of A3 (LD), 100% and lower drawer.
(4) Measure the distance B from the left edge of the paper to 10 mm of the copied image of the ruler.
(5) Check if the distance B is within the range of 10±0.5 mm.
(6) If not, use the following procedure to change values and repeat the steps 3. to 5. above.
<Procedure>
(Adjustment Mode)
→
(Key in the code [306] with the digital keys)
→
[START]
→
(Key in a value (acceptable values: 0 to 255))
→
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
→
(“100% A” is displayed.)
* The smaller the adjustment value, the more the image is shifted to the left and the distance B
becomes narrower (0.085 mm/step).
Fig. 3-7
50
100
150
200
B
Feeding direction
Copied image of the ruler
04/05