e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 36
(2) Connection for main charger adjustment
Fig. 3-30
(3) Connection for transfer/separation charger adjustment
Fig. 3-31
Front cover
opening/closing switch
Ground to the machine
frame (green cable)
(–) terminal:
Connect the white cable of the current
measuring jig
(+) terminal:
Connect the main charger case
Front cover
opening/closing switch
Ground to the machine
(green cable)
(+) terminal:
Connect the red cable of the current
measuring jig
(–) terminal:
Connect the white cable of the
current measuring jig