ADJUSTMENT
3 - 50
(5) Lift up the toner scattering prevention sheet
and insert the gauge “0.45” of the doctor-
sleeve jig into the gap between the devel-
oper sleeve and doctor blade. Tighten the
screws while pressing the doctor blade to the
doctor-sleeve jig lightly.
Note:
Note:
Make sure the mark on the developer sleeve
faces the blade when adjusting the gap.
Fig. 3-50
(6) Insert the gauge “0.40” of the doctor-sleeve
jig into the gap between the developer
sleeve and doctor blade. Confirm that the jig
moves smoothly to the front and rear side,
and the gauge “0.50” cannot be inserted into
the gap.
Fig. 3-51
(7) Confirm that the both ends of the toner scat-
tering prevention sheet are inserted between
the developer sleeve and doctor blade sup-
port holder, and the side seals are attached
on the toner scattering prevention sheet.
Fig. 3-52
Doctor-sleeve jig
Doctor blade
Developer
sleeve
Doctor-sleeve jig
Developer
sleeve
Doctor blade
Doctor blade
support holder
Side seal
Toner scattering
prevention sheet