© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
ADJUSTMENT
3 - 59
3
3.10.3
Adjustment of skew
When an image skew occurs, adjust it according to the following steps, Step 1
→
Step 2
→
Step 3.
Note:
Note:
Perform this adjustment after confirming that the equipment has been adjusted properly.
Prior to this adjustment, of RADF position and height are needed to be adjusted.
(1)
Step 1
Case A: ................Adjust the aligning adjustment position to the rear side “-” of the original
(Chap. 3.10.5).
Case B: ................Adjust the aligning adjustment position to the rear side “+” of the original
(Chap. 3.10.5).
Fig. 3-70
(2)
Step 2
Case C: ................Loosen the fixing screw and hand screw of the right side hinge and then turn
the adjustment screw counterclockwise.
Case D: ................Loosen the fixing screw and hand screw of the right side hinge and then turn
the adjustment screw clockwise.
Note:
Note:
When adjusting, refer to the hinge position (scribed line) and be sure not to move it from the
hinge position ±0.5 mm or further. Otherwise, image failures such as a jitter may occur.
Fig. 3-71
Fig. 3-72
A
B
Paper
Original
White arrow: feeding direction
C
D
Paper
Original
Fixing screw
Adjustment screw
Hand screw
RADF
Front side
04/05