ADJUSTMENT
3 - 60
(3)
Step 3
Case E: ................Adjust the reverse aligning adjustment position to the rear side “-” of the orig-
inal (Chap. 3.10.6).
Case F: ................Adjust the reverse aligning adjustment position to the rear side “+” of the orig-
inal (Chap. 3.10.6).
Fig. 3-73
3.10.4
Automatic adjustment of sensors and initialization of EEPROM
When any of the PC board, original length sensor, read sensor, reverse sensor is replaced with a new
one, make sure to perform the initialization of EEPROM and adjustment of sensors in the Adjustment
Mode (05).
Perform them after removing all originals on the sensor and closing the RADF.
Also, make sure to adjust the tray volume when the initialization of EEPROM and automatic sensor
adjustment have been performed.
Refer to
P. 2-46 "2.2.5 Adjustment mode (05) (e-STUDIO350/450)" for the details.
Errors such as paper jamming may occur if the EEPROM is not initialized and the sensors are not
adjusted after the above mentioned parts were replaced.
E
F
Paper
Original