e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 112
<Preparation>
<Adjustment procedure>
(1) Take off the front cover, right upper cover
and the paper exit tray.
(2) Remove the upper drawer, and then open
the bypass tray and the ADU.
(3) Take off the right front cover.
(4) Open the jam access cover.
Fig. 3-156
(1) Check the scale position. (See Fig. 3-157.)
(2) Loosen 2 screws so that the fuser unit and its
lower stay can move.
(3) • For dogleg image A
Move the lower stay of the fuser unit upward
from the position in Step 1 by 0.5 on the
scale, and then tighten the screws.
• For dogleg image B
Move the lower stay of the fuser unit down-
ward from the position in Step 1 by 0.5 on the
scale, and then tighten the screws.
Note:
Note:
Be sure to match the height of both right and
left scales.
Fig. 3-157
(4) Check the copy image and repeat Step 1 to 3
if further adjustment is needed..
Fig. 3-158
Scale
For dogleg image A:
Move the stay upward
by 0.5 on the scale.
For dogleg image B:
Move the stay downward
by 0.5 on the scale.
04/10