e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
PREVENTIVE MAINTENANCE (PM)
4 - 14
L. RADF (MR-3015)
M. PFP (KD-1011)
N. LCF (KD-1012)
Items to check
Cleaning Lubrication
Replacement
(x1,000 sheets)
Operation
check
Parts list
<P-I>
Remarks
L1
Pickup roller
O
120
P8-I26
L2
Feed roller
O
120
P8-I25
L3
Separation roller
O
120
P6-I6
L4
Original length sensor
O
L5
Registration roller
A
L6
1st small roller
A
L7
2nd small roller
A
L8
Read sensor
O
L9
Read guide
O
L10 Read roller
A
L11 3rd small roller
A
L12 4th small roller
A
L13 Reverse sensor
O
L14 Exit roller
A
L15 Reverse roller
A
L16 Platen sheet
O or A
Items to check
Cleaning Lubrication
Replacement
(x1,000 sheets)
Operation
check
Parts list
<P-I>
Remarks
M1 Pickup roller
(upper/lower)
80/80
P5-I29
M2 Feed roller
(upper/lower)
80/80
P5-I26
M3 Separation roller
(upper/lower)
AV, W2
80/80
P5-I12
*m1
M4 Drive gear (tooth face)
W1
Items to check
Cleaning Lubrication
Replacement
(x1,000 sheets)
Operation
check
Parts list
<P-I>
Remarks
N1
Pickup roller
A
160/160
P4-I30
N2
Feed roller
A
160/160
P4-I28
N3
Separation roller
A
160/160
P5-I12
N4
Drive gear
W1
06/01