© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
TROUBLESHOOTING
5 - 31
5
[E870] RADF open jam
Is the RADF opened?
È
YES
Æ
Remove the original, if any, and close the RADF.
NO
Is the RADF opening/closing sensor adjusted within the specified range?
È
NO
Æ
Adjust the RADF opening/closing sensor.
YES
Is the RADF opening/closing sensor working? (Perform the input check: 03-[FAX]ON/[7]/[D])
|
|
|
|
|
|
|
|
|
|
È
NO
Æ
1) Check if the connector of the RADF opening/closing sensor is discon-
nected.
2) Check if the connector CN6 on the RADF board is disconnected.
3) Check if the connector pins are disconnected or the harnesses are open
circuited.
4) Check if the conductor pattern on the RADF board is short circuited or open
circuited.
5) Replace the RADF opening/closing sensor.
6) Replace the RADF board.
YES
Replace the RADF board.