e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
TROUBLESHOOTING
5 - 34
MJ-1101
Is there any paper remaining on the transport path in the finisher or equipment?
È
Æ
YES Remove the paper.
NO
Is there a disconnection of the connector, incorrect installation or breakage of the entrance
sensor (S1)?
l
l
È
Æ
YES • Reconnect the connector securely.
• Reinstall the sensor correctly.
• Replace the sensor.
NO
Is the gap between the flapper and entrance roller shaft other than 0.60±0.20mm when the
gate solenoid (SOL2) is pulled?
È
Æ
YES Adjust the gap.
NO
Is the harness between the entrance motor (M1) and the finisher control PC board (CN7) dis-
connected or open circuited?
Is the harness between the gate solenoid (SOL2) and the finisher control PC board (CN22)
disconnected or open circuited?
l
È
Æ
YES • Reconnect the connector securely.
• Replace the harness.
NO
Replace the finisher controller PC board.
06/01