5.1.14
Finisher related service call
[CB10] Entrance motor abnormality
[CB11] Buffer tray guide motor abnormality
[CB12] Buffer roller drive motor abnormality
MJ-1101
Is there any mechanical problem when the entrance roller is rotated?
È
Æ
YES Fix
the
mechanism.
NO
Is the harness between the entrance motor (M1) and the finisher control PC board (CN7) dis-
connected or open circuited?
l
È
Æ
YES • Reconnect the connector securely.
• Replace the harness.
NO
1) Replace the entrance motor (M1).
2) Replace the finisher control PC board.
* You receive a [CB11] error when the [ED16] error occurs three times in succession.
MJ-1101
Is there any mechanical problem when the buffer tray guide is opened/closed while the buffer
roller is lifted up?
È
Æ
YES Fix
the
mechanism.
NO
Is the harness between the buffer tray guide motor (M3) and the finisher control PC board
(CN18) disconnected or open circuited?
l
È
Æ
YES • Reconnect the connector securely.
• Replace the harness.
NO
1) Replace the buffer tray guide motor (M3).
2) Replace the finisher control PC board.
MJ-1101
Is there any mechanical problem when the buffer roller is rotated?
È
Æ
YES Fix the drive mechanism.
NO
Is the harness between the buffer roller drive motor (M6) and the finisher control PC board
(CN18) disconnected or open circuited?
l
È
Æ
YES • Reconnect the connector securely.
• Replace the harness.
NO
1) Replace the buffer roller drive motor (M6).
2) Replace the finisher control PC board.